ES105M

The ES105M series is an intergraded outdoor sensor unit for multiple gas sensors. The monitored data is output through RS-485 interface by Modbus protocol. The ES105M sensor unit accepts 10~30Vdc power input voltage and is protected by the IP65 grade Anti-U/V lightweight ABS louver radiation shield. With the optional NBIoT/WiFi gateway WR222 or LoRa end node LC144, the data can be monitor on the cloud platform.
Related Downloads Inquiry cart
Intergraded Device
  • Intergraded multiple sensorsCentral management by sharing a signal output
  • Support Industrial Modbus RTU protocol, RS485
Outdoor Protective Enclosure
  • Prevent direct ultraviolet radiation to the sensors
  • Avoid rapid aging of sensors under harsh environmental conditions such as strong winds, rain, and snow
  • The sensor parts are ventilated for truly sensing the changes in external detection parameters
Flexible Design
  • Customized Shutter Height: Single or multiple parameters both can use small shutter, small size, light weight and easy to install
  • Customized Monitoring parameters: Each parameter is independent and high sensitivity, users can freely integrate monitoring parameters
Optional IoT Router and Cloud Platform - ThingsMaster
  • Support Modbus to connect optional NBIoT Gateway WR222 for one or many sensors
  • Real-time online monitoring, analysis, reporting
  • Remote cloud security and visual management

A: TVOC (Max.3 x A type in one sensor)
Measuring Range 0~60000 ppb (0~60 ppm)                                                               1 ppm=1000 ppb
Resolution 1 ppb
Accuracy  (±8% Full Scale)  ±125 ppb
A: CH2O(Max.3 x A type in one sensor)
Measuring Range 0~5 ppm
Resolution 0.01 ppm
Accuracy ±5% Full Scale
A: O3(Max.3 x A type in one sensor)
Measuring Range 0~10 ppm
Resolution 0.01 ppm
Accuracy ±6% Full Scale
B: O2(Max.2 x B type in one sensor)
Measuring Range 0~25%Vol
Resolution 0.1%Vol
Accuracy ±2% Full Scale
B: H2S(Max.2 x B type in one sensor)
Measuring Range 0~100 ppm
Resolution 1 ppm
Accuracy ±3% Full Scale
B: CH4(Max.2 x B type in one sensor)
Measuring Range 0~100% LEL
Resolution 1% LEL
Accuracy ±5% Full Scale
B: CO(Max.2 x B type in one sensor)
Measuring Range 0~1000 ppm
Resolution 1 ppm
Accuracy ±3% Full Scale
B: NO2(Max.2 x B type in one sensor)
Measuring Range 0~20 ppm
Resolution 0.1 ppm
Accuracy ±3% Full Scale
B: SO2(Max.2 x B type in one sensor)
Measuring Range 0~20 ppm
Resolution 0.1 ppm
Accuracy ±3% Full Scale
B: H2(Max.2 x B type in one sensor)
Measuring Range 0~1000 ppm
Resolution 1 ppm
Accuracy ±3% Full Scale
B: NH3(Max.2 x B type in one sensor)
Measuring Range 0~100 ppm
Resolution 1 ppm
Accuracy ±5% Full Scale
System Parameters
Power Range DC 24V ( Range 10~30V) , Power consumption 1.2W @ DC 24V
System Warm-Up Time  ≥ 5 Minutes ( Gas Sensor Pre-Heat Time)
Enclosure Material Shelter Box, Plastic ABS, Anti-U/V, UL94 V0
Enclosure Protection IP65 Protection Level
Enclosure Dimension 140mm  (Diameter) x  114mm (High)
Communication Modbus RTU protocol, 2-Wire RS-485-A/-B
RS485 Modbus RTU Pulling & Waiting Time ≥ 200mS
Op. Temperature -10 ~ 55°C, 0~95% Humidity, No Condensing
Modbus Register Information
Parameters
Function
Register Add.
(HEX / DEC)
PLC Add.
(Index Number )
Note
Device ID Storage Add. 07D0 H / 2000 2001 R/W , System Factory Default ID: 1
Serial Baud Rate Add. 07D1 H/ 2001 2002 R/W , Default: 2 (9600). 0(2400), 1(4800)
TVOC (ppm) 0007 H/ 7 8 R/O. Actual Value = Read Value / 1000
CH2O (ppm) 0009 H/ 9 10 R/O. Actual Value = Read Value / 100
O3 (ppm) 000A H/ 10 11 R/O. Actual Value = Read Value / 100
O2 (%Vol) 000B H/ 11 12 R/O. Actual Value = Read Value / 10
H2S (ppm) 000C H/ 12 13 R/O. Actual Value = Read Value
CH4 (%LEL) 000D H/ 13 14 R/O. Actual  Value = Read Value
CO (ppm) 000E H/ 14 15 R/O. Actual Value = Read Value
NO2 (ppm) 000F H/ 15 16 R/O. Actual Value = Read Value / 10
SO2 (ppm) 0010 H/ 16 17 R/O. Actual Value = Read Value /10
H2 (ppm) 0011 H/ 17 18 R/O. Actual Value = Read Value
NH3 (ppm) 0012 H/ 18 19 R/O. Actual Value = Read Value
TVOC Calibrate 0057 H/ 87 88 R/W.  Write measured value
CH2O Calibrate 0059 H/ 89 90 R/W. Write measured value x 100
O3 Calibrate 005A H/ 90 91 R/W. Write measured value x 100
O2 Calibrate 005B H/ 91 92 R/W. Write measured value x 10
H2S Calibrate 005C H/ 92 93 R/W.  Write measured value
CH4 Calibrate 005D H/ 93 94 R/W.  Write measured value
CO Calibrate 005E H/ 94 95 R/W.  Write measured value
NO2 Calibrate 005F H/ 95 96 R/W. Write measured value x 10
SO2 Calibrate 0060 H/ 96 97 R/W. Write measured value x 10
H2 Calibrate 0061 H/ 97 98 R/W.  Write measured value
NH3 Calibrate 0062 H/ 98 98 R/W.  Write measured value
R/W: Read & Write, R/O: Read Only
Model Description
ES105M-A1-A2-A3-B1-B2 O105utdoor Multi Air Sensor RS485 Modbus, 10-30V Power, Max 3 x A type and 2 x B Type
A: TVOC TVOC Sensor Module 0~60PPM for ES105M
A: CH2O CH2O Sensor Module 0~5PPM for ES105M
A: O3 O3 Sensor Module 0~10PPM for ES105M
B: O2 O2 Sensor Module 0~25%Vol for ES105M
B: H2S H2S Sensor Module 0~100PPM for ES105M
B: CH4 CH4 Sensor Module 0~100% LEL for ES105M
B: CO CO Sensor Module 0~1000PPM for ES105M
B: NO2 NO2 Sensor Module 0~20PPM for ES105M
B: SO2 SO2 Sensor Module 0~20PPM for ES105M
B: H2 H2 Sensor Module 0~1000PPM for ES105M
B: NH3 NH3 Sensor Module 0~100PPM for ES105M
Package List
1 x Multiple Sensor Shelter Box
1 x QIG